赵INW 发表于 2023-7-31 18:12

迅达300P电梯故障代码171

故障代码:171

品牌:迅达

型号:300P,VF20/30参数错误 0x01-0x80 (parameter-ID): Drive parameter in PCT out of range0x01: P_VF20_30_TACHO_FACTOR 0x02: P_VF20_30_KSE_DISTANCE 0x03: P_VF20_30_KSERE_DISTANCE 0x04: P_VF20_30_GAP_LENGTH 0x05: P_VF20_30_LOAD_TYPE 0x06: P_VF20_30_DRIVE_RES_1 0x07: P_VF20_30_DRIVE_RES_2 0x08: P_VF20_30_DRIVE_RES_3 0x09: P_VF20_30_DRIVE_RES_4 0x20: P_VF20_30_FN 0x21: P_VF20_30_VKN 0x22: P_VF20_30_FC_MAX_R 0x23: P_VF20_30_MM_IMP 0x24: P_VF20_30_FT_RU1 0x25: P_VF20_30_DELTA_U 0x26: P_VF20_30_frequency converter_RES_ 0 0x27: P_VF20_30_T_DIFF 0x28: P_VF20_30_T_AUF 0x29: P_VF20_30_U_END 0x2A: P_VF20_30_S_KBR_2 0x2B: P_VF20_30_ 频率 converter_RES_ 0x2C: P_VF20_3 频率converter_RES_0_ 0x80: P_VF20_30_SELECTOR_TRANS_TABLE 0x00: 没有驱动-PCT 0xFE: 条件 U_END >= DELTA_U 不旅行 0xAA (GENERAL_PARAM): 储存普通驾车参数 (编码器因素, K SE-距离, KSERE-距离, 缺口GAP-长度, 载入类型) 输出范围. 0xBB (频率 converter_PARAM): 储存特殊驾车参数 (FN, VKN, MM_IMP, S_KBR_2, FT_RU1, DELTA_U, FC_MAX_R, T_DIFF, T_AUF, U_END) 输出范围
页: [1]
查看完整版本: 迅达300P电梯故障代码171

免责声明:电梯阁所发布的一切电梯相关软件、调试说明、图纸等资料仅限用于学习和研究目的;不得将上述内容用于商业或者非法用途,否则,一切后果请用户自负。本站信息来自网络用户发表,版权争议与本站无关。您必须在下载后的24个小时之内,从您的硬盘中彻底删除上述内容。如果您喜欢该资料,请支持正版,得到更好的正版服务。如有侵权请邮件联系我们处理。